Inverted Bucket Steam Traps IB 12

admin

DESCRIPTION

IB12 series inverted bucket steam traps are recommended for all services where the most important requirements are overall operating efficiency and long, trouble-free service life.

They operate intermittently, either wide open or tightly closed and are therefore best suited for service at medium and high steam pressures. Connections are female screwed for horizontal installation.

MAIN FEATURES

  • Intermittent discharge.
  • Discharges condensate at steam temperature.
  • Unaffected by water hammer and vibrations.
  • Easy to maintain.

Inverted Bucket Steam Traps IB30S & IB30SS

admin

DESCRIPTION

IB30 series inverted bucket steam traps are recommended for all services where the most important requirements are overall operating efficiency and long, trouble-free service life. They operate intermittently, either wide open or tightly closed and are therefore best suited for service at medium and high steam pressures. Connections are female screwed or flanged.

MAIN FEATURES

  • Intermittent discharge.
  • Discharges condensate at steam temperature.
  • Unaffected by water-hammer and vibrations.
  • Easy to maintain.

Inverted Bucket Steam Traps IB30S

admin

DESCRIPTION

IB30 series inverted bucket steam traps are recommended for all services where the most important requirements are overall operating efficiency and long, trouble-free service life. They operate intermittently, either wide open or tightly closed and are therefore best suited for service at medium and high steam pressures. Connections are female screwed or flanged.

MAIN FEATURES

  • Intermittent discharge.
  • Discharges condensate at steam temperature.
  • Unaffected by water-hammer and vibrations.
  • Easy to maintain.

Inverted Bucket Steam Traps IB35S & IB35SS

admin

DESCRIPTION

IB35 series inverted bucket steam traps are recommended for all services where the most important requirements are overall operating efficiency and long, trouble-free service life. They operate intermittently, either wide open or tightly closed and are therefore best suited for service at medium and high steam pressures. Connections are female screwed or flanged.

MAIN FEATURES

  • Intermittent discharge.
  • Discharges condensate at steam temperature.
  • Unaffected by water-hammer and vibrations.
  • Easy to maintain.

Inverted Bucket Steam Traps IBB 12

admin

DESCRIPTION

IBB12 series inverted bucket steam traps are recommended for all services where the most important requirements are overall operating efficiency and long, trouble-free service life. They operate intermittently, either wide open or tightly closed and are therefore best suited for service at medium and high steam pressures. Connections are female screwed for horizontal installation.

MAIN FEATURES

  • Intermittent discharge.
  • Discharges condensate at steam temperature.
  • Unaffected by water hammer and vibrations.
  • Easy to maintain.

Thermodynamic Steam Traps DT46

admin

DESCRIPTION

Thermodynamic DT46 disc steam traps are compact and lightweight-easy to install traps, excellent for high pressure systems, including steam tracing applications.

The insulation cover insures a consistent operation and makes it particularly suitable for those applications where the weather conditions, such as rain and wind, may affect the normal operation. These traps have only one moving part and offer a wide operating range, without adjustment. Connections are female screwed or flanged.

MAIN FEATURES

  • Intermittent discharge.
  • Standard insulation cover
  • Operates on superheated steam.
  • The seat and disc can be easily replaced in field without removing the trap from the line.
  • Unaffected by water hammer and vibrations
  • Built-in easy-to-clean strainer.

Thermodynamic Steam Traps DT42/2

admin

DESCRIPTION

Thermodynamic DT42/2 disc steam traps are compact and lightweight-easy to install traps, excellent for high pressure systems, including steam tracing applications. These traps have only one moving part and offer a wide operating range, without adjustment. Connections are female screwed or flanged.

MAIN FEATURES

  • Intermittent discharge.
  • Operates on superheated steam.
  • The seat and disc can be easily replaced in field without removing the trap from the line.
  • Unaffected by water hammer and vibrations.
  • Built-in easy-to-clean strainer.

Thermodynamic Steam Traps DT 40S

admin

DESCRIPTION

Thermodynamic DT40S disc steam traps are compact and lightweight-easy
to install traps, excellent for high pressure systems, including steam tracing
applications. These traps have only one moving part and offer a wide
operating range, without adjustment. Connections are female screwed.

MAIN FEATURES

  • Intermittent discharge.
  • Operates on superheated steam.
  • The disc can be easily replaced in field without removing the trap from the line.
  • Unaffected by water-hammer and vibrations.
  • Integral seat.